Leave Your Message
Products Categories
Featured Products

TJS-6 Series(Continue)cold heading machine

The diameter of steel bars or steel wires should meet the requirements of the multi-station cold heading machine, and steel bars (wires) that are too thick or too thin cannot be cold-headed;

    Main technical parameters:

    MODEL

    unit

    TJS-64L-120

    TJS-65L-170

    TJS-65L-120

    TJS-66L-170

    TJS-66L-120

    Stons Qunty

    No.

    4

    5

    5

    6

    6

    Forming Force

    Kgs

    40000

    45000

    45000

    50000

    50000

    Max. Cut- -off Diameter

    mm

    Φ9

    Φ9

    Φ9

    Φ9

    Φ9

    Max. Cut- -off L ength

    mm

    110

    110

    110

    110

    110

    Producton Spedpcs

    Pcs/min

    60-200

    60-180

    60-180

    60-180

    60-180

    P.KO Stroke

    mm

    25

    25

    25

    25

    25

    KO Stroke

    mm

    85

    110

    85

    110

    85

    Stroke

    mm

    120

    170

    120

    170

    120

    Cut off Die Diameter

    mm

    Φ28*45L

    Φ28*45L

    Φ28*45L

    Φ28*45L

    Φ28*45L

    Punch Diameter

    mm

    Φ38*115L

    Φ38*115L

    Φ38*115L

    Φ38*115L

    Φ38*115L

    Main Die Diameter

    mm

    Φ56*150L

    Φ56*150L

    Φ56*150L

    Φ56*150L

    Φ56*150L

    Die Pitch

    mm

    60

    60

    60

    60

    60

    Normal Sina of Bolt

    mm

    M3-M8

    M3-M8

    M3-M8

    M3-M8

    M3-M8

    Shank Length of Blank

    mm

    10-60

    10-100

    10-60

    10-100

    10-60

    Main Motor Power

    KW

    22KW-8

    30KW-8

    30KW-8

    37KW-8

    37KW-8

    Main Motor voltage

    V

    380V

    380V

    380V

    380V

    380V

    Main Motor frequency

    HZ

    75HZ

    75HZ

    75HZ

    75HZ

    75HZ

    Main Motor speed

    r/min

    750

    750

    750

    750

    750

    Pump power

    W

    2*180W(1/4HP)

    2*180W(1/4HP)

    2*180W(1/4HP)

    2*735W(1HP)

    2*735W(1HP)

    Oil consumption

    L

    200L

    200L

    200L

    200L

    200L

    Volume(L*W*H)

    M

    3.5*1.39*1.8

    3.5*1.47*1.86

    3.5*1.48*1.86

    3.5*1.55*1.86

    3.5*1.55*1.86

    Weight

    Ton

    5.8

    6.3

    6.3

    6.7

    6.7

    FAQ

    Precautions when using cold heading machine:

    1. The diameter of steel bars or steel wires should meet the requirements of the multi-station cold heading machine, and steel bars (wires) that are too thick or too thin cannot be cold-headed;

    2. Within the allowable range of the cold heading diameter of the punching and heading machine, the position of the clamp (screw in or out) can be adjusted according to the required anchor head size, so as to obtain the appropriate extension allowance of the steel bar (wire);

    3. In the 120~130mm area of the cold heading part of the steel bar (wire), rust must be removed and straightened;

    4. The ends of the steel bars should be ground flat to ensure the accurate shape of the cold heading anchor head;

    5. After the steel bars are heading, they must undergo a tensile test to check whether the strength of the anchor head is qualified.

    Incorrect processing methods will cause cold heading machine failures. The following introduces common failures and solutions of cold heading machines:

    1. Before starting up, carefully check whether the fasteners of the equipment are locked and whether the safety protection devices are intact, and check frequently during work. Looseness due to severe vibration can also cause malfunctions.

    2. After the equipment is adjusted, first pull the flywheel to check whether the various mechanisms are working normally. After removing the lever for the pulley, start the motor to see if the machine is operating normally.

    3. Protective devices must be added to prevent rupture and accidents.

    4. If a malfunction occurs, multi-station cold heading must be stopped immediately to identify the cause and eliminate hidden dangers.

    description2